| Basic Information | ||
| Item | Specification | |
| Product Model | Example: S13-M-100/10 (S=Three-Phase, 13=Efficiency Class, M=Hermetically Sealed, 100=Rated Capacity kVA, 10=HV Rated Voltage kV) | |
| Rated Capacity(Sn) | 50kVA~2500kVA (ONAN: 100% rated capacity; ODAF: 130% rated capacity) | |
| Phase | Three-Phase (Standard) / Single-Phase (Customizable) | |
| Rated Frequency(fn) | 50Hz / 60Hz (±1% tolerance) | |
| Connection Group | Dyn11 (Default) / Yyn0 (Optional, per IEC 60076-1) | |
| Environmental & Operating Conditions | ||
| Ambient Temperature | -25℃~40℃ (-40℃ optional with anti-freeze additive) | |
| Altitude | ≤1000m (5% derating at 1500m, 10% at 3000m) | |
| Humidity | ≤90% @25℃ (no condensation); ≤50% @40℃ | |
| Seismic Resistance | GB 50260-2013, 7-degree intensity (0.15g acceleration) | |
| Protection Class | IP20 (Indoor) / IP23 (Outdoor, dust/rain protection) | |
| Losses & Impedance (Efficiency Core) | ||
| Parameter | S13-100/10 Example | Test Conditions |
| No-Load Loss (Po) | ≤170W | Rated voltage, rated frequency |
| Load Loss (Pk) | ≤1050W | Rated current, 75℃ reference temp |
| Short-Circuit Impedance (Uk%) | 4%~6% | ±10% tolerance at 75℃ |
| No-Load Current (Io%) | ≤1.2% (≤0.8% for large capacity) | Rated voltage |
| Efficiency Compliance: GB 20052-2024 Class 2 (S13) / Class 1 (S15, 15-20% lower losses than S13) | IEC 60076-11 IE2/IE3 equivalent for EU markets | ||
| Example S13-250/10 Key Specs | ||
| Item | Value | |
| Rated Capacity | 250kVA | |
| HV/LV Voltage/Current | 10kV/14.43A;0.4kV/360.8A | |
| No-Load/Load Loss | ≤320W / ≤2250W | |
| Short-Circuit Impedance | 4.5% | |
| Core Material | 30Q130 Silicon Steel | |
| Cooling Method | ONAN | |
| Protection Class | IP23 | |
| Customization available for special voltages, high-altitude, or explosion-proof requirements. All parameters verified by third-party labs. | ||
Laminated structure with high-grade grain-oriented silicon steel minimizes eddy current and hysteresis losses, achieving up to 98% efficiency—cuts energy consumption and operational costs long-term.
Advanced heat-dissipating design enables reliable work in -20°C to 60°C, avoiding overheating issues.
Flexible voltage (110V-33kV), capacity (5kVA-5MVA), and enclosure (IP23-IP65) options fit industrial, renewable energy, and commercial needs.
Compliant with IEC/ANSI standards, it has a 25+ year lifespan and <55dB noise, ensuring long-term stable, quiet operation.
Powers heavy machinery (e.g., manufacturing assembly lines, metal processing equipment), industrial control systems, and factory power distribution networks—handles fluctuating loads stably to ensure uninterrupted production.
Integrates with solar photovoltaic (PV) farms and wind power plants, converting unstable renewable energy into grid-compatible electricity for efficient power transmission to the public grid.
Supplies power to commercial buildings (shopping malls, office towers) and residential communities, supporting HVAC systems, lighting, and household/appliance electrical needs with low noise and high efficiency.
Used in medium/high-voltage power grids (e.g., regional substations), stepping up/down voltages to match long-distance transmission and end-user demand, ensuring safe and efficient power supply.
The S13 transformer model complies with GB 20052-2024 Class 2 efficiency standards. It features high-grade grain-oriented silicon steel that minimizes losses, offering 15-20% higher losses than Class 1 (S15) models, and aligns with IEC 60076-11 IE2/IE3 equivalent requirements for European markets.
Yes, high customizability is available. The rated capacity ranges from 50kVA up to 2500kVA (or custom ranges from 5kVA to 5MVA), and the voltage ratings can be customized from 110V up to 33kV to fit specific industrial, residential, or renewable energy system requirements.
Standard operating conditions support ambient temperatures between -25℃ and 40℃ (with optional anti-freeze additives down to -40℃), altitudes ≤1000m (with derating at higher altitudes), and relative humidity ≤90% at 25℃. They are designed to withstand 7-degree seismic intensity according to GB 50260-2013 standards.
The default cooling method is ONAN (Oil Natural Air Natural), with options for ODAF (Oil Directed Air Forced) to boost capacity. The default connection group is Dyn11, with Yyn0 available as an option in compliance with IEC 60076-1.
Designed with a durable and low-noise core, these transformers operate with noise levels kept under 55dB. This makes them ideal for commercial and residential installations where quiet, stable operation is required.